DSC HS2128 Reference Manual page 234

Powerseries neo alarm controller
Hide thumbs Also See for HS2128:
Table of Contents

Advertisement

HS2ICNP, HS2LED HS2TCHP.
The following wireless keys can also be used in SIA compatible installations: PG9929, PG9939,PG9949.
Note: For models PG9929 and PG9939, the panic/emergency key shall be disabled for SIA compliant installations.
For a list of the default values programmed when the unit is shipped from the factory, and for other programming information,
refer to the following table.
The following optional subassembly modules also bear the SIA CP-01-2010 classification and may be used if desired:
HSM2108 zone expander, HSM2208 PGM output module, HSM2300 auxiliary power supply, HSM2204 output module,
HSM2HOST9 2-way wireless transceiver, PG9901 indoor siren, PG9911 outdoor siren, and 3G2080(R)/ TL2803G(R)/ TL280
(R) cellular and PSDN communication module.
Caution
For SIA FAR installations use only modules/devices that are listed on this page.
l
Fire Alarm Verification feature (Auto Verified Fire Zone type [025]) is not supported on 2-wire smoke detectors zones,
l
model FSA-210B(T)(S)(ST)(LST)(R)(RT)(RD)(RST)(LRST). This feature may be enabled for 4-wire smoke detectors
only (FSA-410B(T)(S)(ST)(LST)(R)(RT)(RST)(LRST) and wireless detectors PG9916/PG9926). The fire alarm delay
is 60s.
Call Waiting Cancel (Section [382], option 4) on a non-Call Waiting line will prevent successful communication to the
l
supervising station.
All system smoke detectors must be tested annually by conducting an Installer Walk Test. Prior to exiting Walk Test
l
mode, a sensor reset must be done on the system, [*][7][2], to reset all latching 4-wire smoke detectors. Refer to the
installation instructions supplied with the detector for details.
Notes
Programming at installation may be subordinate to other UL requirements for the intended application.
l
Cross zones have the ability to individually protect the intended area (e.g. motion detectors which overlap).
l
Cross zoning is not recommended for line security Installations nor is it to be implemented on exit/entry zones.
l
This control panel has a communication delay of 30 seconds. It can be removed or increased up to 45 seconds by
l
the end user with installer consultation.
The system shall be installed with the sounding device activated and the communicator enabled for transmission
l
using SIA or CID format.
ULC commercial burglary installations require DEOL resistors.
l
SIA Feature Pro-
Comments
gramming Section
Exit Time
Access to Entry and Exit delays and Bell Time Out for the system.
[005]>[001], option 3
Exit Delay Restart
Opening a Delay zone door after it has already been opened and closed during
an exit delay restarts the exit delay timer.
[018], option 7
Auto Stay Arm on Un-
vacated Premises
Function key: Forces the system to arm in Stay mode if the occupant does not exit
the premises after pressing the Away function key.
[001]>[001]-[128] Zone
type 05, 06,09
Appendix 4: Regulatory Approvals
- 234 -
Range/Default Requirement
Range:45-
255 seconds
Required
Default: 60
(programmable)
sec.
Default:
Required
Enabled
If no exit after
full arm
Required
Default:
Enabled