Section 5: System Operation
If no Stay/Away zone types are programmed, the alarm system arms in Away mode.
Note: Do not use this function with CP-01 installations.
[03] Stay Arm
Only perimeter zones are armed. Interior zones are bypassed regardless of whether or not delay zones are tripped during
the exit delay.
[04] Away Arm
All interior and perimeter zones are armed. CP-01 panels require an exit through a delay zone during the exit delay or the
system will arm the perimeter zones only.
[05] No-Entry Arm [*][9]
All Delay 1 and Delay 2 zones become instant zones. If a door or window is opened the system goes immediately into alarm.
This function is typically used when no occupants are expected to return to the site during the armed period. Activation of this
function key requires an access code. This function only works while the system is disarmed.
See "[*][9] No-Entry Arming" on page 60 for more information.
[06] Chime On/Off
This function turns the door chime on or off and is the equivalent of pressing [*][4]. The alarm system must be disarmed to
use this function. If option 7 in section [023] is enabled, this function key requires an access code.
[07] System Test
This function performs a system test when pressed and is the equivalent of entering [*][6][Access Code][04]. The alarm sys-
tem must be disarmed to use this function. See "[*][6] User Functions" on page 55 for more information.
[09] Night Arm
All perimeter and interior zones, excluding Night zones, are armed. This key only works while the system is disarmed or
armed in Stay mode.
If no Night type zones are programmed, the alarm system arms in Away mode with an audible exit delay. Exit delay is silent.
Arming in this mode activates the Away Arming PGM output.
[12] Global Stay Arm
This function arms all partitions assigned to the user in Stay mode, provided they are ready to arm. If a partition is not ready,
the system cannot be armed. An access code is required with this option.
[13] Global Away Arm
This function arms all partitions assigned to the user in Away mode, provided they are ready to arm. If a partition is not ready,
the system cannot be armed. An access code is required with this option.
[14] Global Disarming
This function disarms all partitions assigned to the user. An access code is required with this option.
[16] Quick Exit
Pushing this key allows the user to open and close an entry/exit door without disarming the system. This function is equi-
valent to entering [*][0] at the keypad while the partition is armed. If quick exit is not enabled on the system, or if the system is
disarmed, pressing this key causes an error tone. An access code is not required to use this key. See "[015] System Option
3" on page 98 for more information.
[17] Arm Interior
This key removes or enables automatic bypass on all Stay/Away zones (equivalent to pressing [*][1] while armed).
If this function is performed while stay armed and, Night zones are programmed, the system arms in Night mode. If no Night
zones are programmed, the system arms in Away mode. If armed in Night or Away mode, this key switches the system back
to Stay mode. Pressing this key does not switch the arming mode from Night to Away.