Section 5: System Operation
Event Buffer
Menu: [*][6][Master Code] > Event Buffer
Keypad: [*][6][Master Code] > [*]
This option is used to view system events stored in the event buffer.
Events are listed in the order they occurred, starting with the most recent. The time and date are listed for all events. Some
events may have a second screen with a description. An asterisk (*) on the first screen indicates that a second screen is
available.
If programmed, the event buffer automatically uploads to DLS/SA when it reaches 75% capacity. See section [410] option 3.
System Test
Menu: [*][6][Master Code] > System Test
Keypad: [*][6][Master Code] + 04
Select this option to test the alarm system's bell output, keypad buzzer and lights, communicator and standby battery.
Time and Date
Use this section to program the alarm system clock.
Menu: [*][6][Master Code] > Time and Date
Keypad: [*][6][Master Code] + 01
Enter time and date using the following format: (HH:MM); (MM-DD-YY). Valid time entries are 00-23 hours, 00-59 minutes.
Valid date entries are 01-12 months, 01-31 days.
Other programming options that may affect this user function:
See "[901]/[902] – Daylight Savings Begin/End" on page 78.
Auto-Arm/Disarm
Menu: [*][6][Master Code] > Auto Arm/Disarm
Keypad: [*][6][Master Code] + 02
With this feature enabled, the alarm system automatically arms in away mode (stay/away zones active) or disarms at a pro-
grammed time each day (see Auto-Arm Time below). The keypad emits three beeps to indicate the system is armed and one
long beep to indicate it is disarmed.
All arming inhibit features such as latching tampers, AC inhibit, etc. also inhibit Auto Arming and send the Auto Arm Can-
cellation code.
Auto-Arm Time
Menu: [*][6][Master Code] > Auto Arm Time
Keypad: [*][6][Master Code] + 03
This function is used to program the time of day each alarm system partition automatically arms. To program an auto-arm
time, select a day of the week and then key in the time. On LED/ICON keypads, zone lights 1-7 represent Sunday to
Saturday. Valid time entries are 00-23 hours: 00-59 minutes.
At the programmed time, the keypad buzzers beep for a programmed duration (for ULC commercial burglary installations
minimum duration is 10 minutes) to warn that automatic arming is in progress. The siren also squawks once every 10
seconds during this warning period if programmed to do so. When the warning period is complete, the exit delay elapses
then the system arms in away mode.