Priority (Gas, Heat, Sprinkler and 24-Hour Latching Zones)
l
Holdup (Holdup zones)
l
Output follows pulse timer (See "[008] PGM Timer Programming" on page 79).
l
Duress
l
Emergency
l
CO Alarm
l
Fire Supervisory
l
Fire trouble
l
This output does not activate during pre-alert or delays.
In the armed state, the output deactivates only once the system is disarmed.
If an alarm activates this output in the disarmed state, the output deactivates when a user enters a valid access code during
bell timeout. The output also deactivates if someone arms the system after the bell timeout has expired.
If assigned to a single partition, the output activates when an enabled alarm event occurs on the assigned partition. When
assigned to multiple partitions, the output activates when an alarm occurs on any partition and, if configured to latch, will
deactivate when any partition is disarmed. (or a valid disarming procedure is used).
157 – System Tamper
This output activates when any tamper condition is present and deactivates when all tamper conditions are cleared (if set for
steady operation). If set for a pulsed operation, the output deactivates when the PGM Output timer expires. These tampers
include zone tampers (DEOL), case tampers, TLM trouble, RF jam, and all zone and device tampers.
Note: This PGM does not activate for alternate communicator fault.
161 – DC Trouble
This output activates when one of the following low battery conditions is detected:
Alarm controller low or absent battery
l
Module low or absent battery
l
Wireless zone low battery
l
Wireless keypad low battery
l
Wireless siren low battery
l
Wireless key low battery
l
The output can be configured to follow the state of the low battery trouble(s) or it can activate for a period of time and auto-
matically restore.
165 – Proximity Tag Used
This output activates when the selected proximity tag is presented.
Assign this output to a user by entering a user number from 0002 to 1000. To enable this attribute for all proximity tags, enter
000 in PGM attribute [011]. See "[007] - [008] PGM Configuration" on page 79.
166 – Partition Prox Used
This output activates when a proximity tag is presented at a system keypad equipped with a proximity tag reader, including
global keypads. The proximity tag must be assigned to a valid user and the PGM must be assigned to a partition that the
user has permission to access.
Assign this output to a partition in section [007], PGM Partition Assignment. Use section [011], PGM Configuration Options, to
assign a schedule. When [011] is programmed as 000, the output activates any time a valid proximity tag is presented. When
[011] is programmed as 1-4, the output activates only when the proximity tag is presented during the scheduled interval.
Section 6: Programming
- 84 -