savings clock adjust. Daylight Savings Time programming should not conflict with the Auto-arm and Test Transmissions pro-
gramming.
OFF: The alarm system makes no automatic time adjustments for Daylight Saving time.
7 – Silence Chime During Quick Exit Delay
ON: Door chime does not sound during quick exit.
OFF: Door chime sounds during quick exit, according to zone settings.
8 – Bell Squawk on Away Arm/ Disarm Only
ON: Bell Squawks are only heard when away arming, as well as when disarming from Away mode. This feature prevents the
siren from activating when arming in stay and night modes.
OFF: Bell Squawks are heard during all types of arming and disarming.
Note: This option follows the "Bell Squawk Attribute" features if they are enabled.
[018] System Option 6
1 – Test Transmission Exception
ON: The alarm system does not send a test transmission if a transmission was sent to the receiver within the programmed
interval as set in section [377]>See "[003] – Periodic Test Transmission Cycle" on page 122.
OFF: Test transmissions are always sent at the programmed interval.
2 – Real-Time Bypass Reporting
ON: When a non-24-hour zone is bypassed in [*][1], the system immediately logs and communicates the bypass status of the
zone.
Global Zones: 24-hour and non-24 hour zone bypasses are logged and communicated in real time. Non-24 hour zone unby-
pass events are generated when the last assigned partition is disarmed.
OFF: When a non 24-hour zone is bypassed in [*][1], the system logs and communicates the bypass status of the zone only
after the partition is armed. This option is applied regardless of how zones are bypassed in [*][1], recall bypass group, clear
all bypasses, bypass open zones, bypass recall as well as other methods such as bypassing via ITv2 or DLS.
Global Zones: 24-hour zone bypasses are logged and communicated in real time. Non 24-hour zone bypass events are
logged and communicated when armed. Non 24-hour zone unbypass events are logged and communicated when the last
partition is disarmed.
3 – Armed Status PGM ON at End of Exit Delay
ON: PGMs are activated at the end of exit delay. This applies to PGMs with one of the following armed status attributes:
115 System Armed Status PGM
l
116 Away Armed Status PGM
l
117 Stay Armed Status PGM
l
120 Away Armed with No Zone Bypass Status
l
129 Partition Status Alarm Memory
l
OFF: PGMs are activated at the beginning of exit delay. This applies to PGMs with one of the armed status attributes listed
above.
4 – Not Used
5 – Keypad Buzzer Follows Bell
ON: The keypad buzzer activates with all bell activity for the selected partition.
OFF: The keypad buzzer only activates with alarms programmed to do so.
Section 6: Programming
- 101 -