Advertisement

05 – Loss of Clock
ON: activates on loss of clock trouble condition.
OFF: does not activate on loss of clock trouble condition.
06 – DC Trouble
ON: activates if a panel low or no battery trouble is detected, or if an HSM2204/2300 1-4 low or no battery trouble is
detected.
OFF: does not activate on DC Trouble condition.
07 – Bus Voltage
ON: activates when a system module has measured a low Aux voltage.
OFF: does not activate for a module low voltage trouble.
08 – AC Trouble
ON: activates when any system device detects an AC Failure condition.
OFF: does not activate for AC Failure conditions.
09 – Device Fault
ON: activates if one of the following device fault conditions is present:
zone 001 – 128 fault
l
keypad 01 – 16 fault
l
siren 01 – 16 fault
l
repeater 01 – 08 fault
l
fire trouble
l
CO trouble
l
gas trouble
l
heat trouble
l
freeze trouble
l
probe disconnected trouble
l
self test trouble
l
OFF: does not activate if a device fault condition is present.
10 – Device Low Battery
ON: activates if any of the following device low battery conditions is present:
zone 001 – 128
l
keypad 01 – 16
l
siren 01 – 16
l
repeater 01 – 08
l
user 01 – 32 (wireless keys)
l
OFF: does not activate if a device low battery condition is present.
11 – Device Tamper
ON: activates if any of the following device tamper conditions is present:
zone 001 – 128
l
keypad 01 – 16
l
siren 01 – 16
l
repeater 01 – 08
l
OFF – does not activate if a device tamper condition is present.
Section 6: Programming
- 90 -