Note: For UL/ULC listed installations, do not turn off the keypad sounder.
Authorize Firmware Update
Menu: [*][6][Master Code] > Authorize Update
Keypad: [*][6][Master Code] + 17
This function is used to give authorization to the system to start the firmware upgrade process after all firmware upgrade files
for the keypads, HSM2HOST, control panel and alternate communicator have been fully downloaded.
Once this option is activated, the keypads and system automatically exit [*][6] and indicate that the firmware update is in pro-
gress.
Interactive Services
Menu: [*][6][Master Code] > Interactive Serv
Keypad: [*][6][Master Code] + 18
This function is used by an alternate communicator to open the Interactive Services menu.
5.7.8 [*][7] Command Outputs 1-4
Menu: [*][7][master code if required] > Output Control
Keypad: [*][7][master code if required]
This option is used to activate or deactivate command outputs 1 to 4 for each partition and enable command outputs to fol-
low a schedule.
Using an LCD keypad:
1. Press [*][7] to enter Output Control mode.
2. Scroll to an output and press [*] to select it, or key in a command output number. The output is toggled on or off or can
activate for a fixed period of time.
3. Press [*][7][9] and enter the system master or supervisor code. Scroll to each command output and press [*] to enable or
disable the use of a programmed schedule to control the output.
Using an LED/ICON keypad:
1. Press [*][7] to enter Output Control mode.
2. Key in a command output number. The output is toggled on or off.
3. Press [*][7][9] and enter the system master or supervisor code. Press digits 1 to 4 to enable or disable the use of a pro-
grammed schedule to control the output.
Note: If no command outputs are programmed this function is not available. Other programming options that may affect this
user function:
See "121-124 – Command Outputs 1-4" on page 81
5.7.9 [*][8] Installer Programming
Use this option to place the alarm system in Installer Programming mode. Installer Programming is used to manually pro-
gram alarm panel and module options. An installer's code is required to access this function.
Installer Programming is exited automatically after 20 minutes of inactivity.
When viewing data in sections with an LCD keypad, use the [<] and [>] keys to scroll.
Other programming options that may affect this user function:
See "[990] Installer Lockout Enable/Disable" on page 137
Section 5: System Operation
- 59 -