Appendix 7: Specifications - DSC HS2128 Reference Manual

Powerseries neo alarm controller
Hide thumbs Also See for HS2128:
Table of Contents

Advertisement

Zone Configuration
16, 32, 64, or 128 wireless zones supported and up to 8 hardwired zones available on the controller
l
40 zone types and 14 programmable zone attributes
l
Zone configurations available: normally closed, single EOL and DEOL supervised
l
Hardwired zone expansion (fully supervised) available using the model HSM2108 (eight zone expander module)
l
Wireless zone expansion (fully supervised) available using the HSM2Host 2-way wireless integration module (oper-
l
ating at 915MHz (North America), 433MHz (Europe) and 868MHz (international)
Access Codes
Up to 1002 access codes: 1000 (level 2-EN), one installer code (level 3-EN), and one maintenance code
l
Programmable attributes for each user code (see "Access Code Attributes" on page 53)
l
When using 8-digit access codes, the minimum number of variations are:
l
HS2016-4: 2083333
HS2032: 1388888
HS2064/HS2128: 1052631
HS2064 E: 200000
HS2128 E: 100000
Warning Device Output
Integral sounder capable of 85 dB @ 3m, self-powered type Z
l
2 remote, wireless indoor/outdoor warning devices supported: models PGX901 (indoor), PGX911 (outdoor) (X=4, 8,
l
or 9)
Programmable as steady, pulsed or temporal three (as per ISO8201) and temporal four (CO alarm) output
l
Warning device sounds alarms in the following priority: fire, CO, burg
l
Memory
CMOS EEPROM memory
l
Retains programming and system status on AC or battery failure for 20 years min. (not verified by UL)
l
Power Supply - North America
Transformer: DSC PTD1640U, PTD1640
Primary: 120V, 60Hz Class II
Secondary: 16.5VAC, 40VA Max.
Power Supply - International
Input ratings: 220V-240Vac, 50/60Hz, 200mA
l
Transformer required, mounted in the same enclosure, permanently connected
l
Transformer secondary ratings: 16.5Vac, 40VA min.
l
Note: For installations using the transformer mounted inside the cabinet, replace fuse only with the same type (20mm) rated
250V/315mA.
Regulated power supply:
1.7A regulated, supervised and integral to the control unit
l
Type A as per EN50131-6 Standard
l
700mA auxiliary supply, 12V DC
l
Positive temperature coefficient (PTC) for Bell, Aux+ and Battery terminals
l
Reverse battery detection/protection
l
Supervision for AC power and low battery
l

Appendix 7: Specifications