DSC HS2128 Reference Manual page 236

Powerseries neo alarm controller
Hide thumbs Also See for HS2128:
Table of Contents

Advertisement

Swinger Shutdown
Enable
Access to swinger shutdown, transmission delay and cross zone attributes. Zone
attribute option 6 (Swinger Shutdown enabled) is ON.
[002]>[001] - [128], option
6 ON
24-Hr. Auto-verified Fire
Access to 24-Hr. Auto-verified Fire
[001]>[001]-[128], Zone
Activates if Not restored within the specified time.
type 025 ON
Call Waiting Cancel
Access to the dialing sequence used to disable call waiting. Call waiting string can
be programmed in [304]
[382], option 4 OFF
System Test:
The system activates all keypad sounders, bells or sirens for 2 seconds and all
[*][6] Master Code, option
keypad lights turn on. Refer to user manual (part no. 29008365).
04
Walk Test Mode:
This mode is used to test each zone on the system for proper functionality.
[*][8][Installer code][901]
Walk Test
Communications
Enables communication of zone alarms while walk test is active.
[382], option 2
Walk Test Start/ End
Reporting Codes
Access to the reporting codes for walk test start and end times.
[308][401], options 1 and 2
EU Compliance Statement
This Product (HS218/HS2064/HS2032/HS2016) is in Conformity with EMC Directive 2004/108/EC based on results using harmonized
standards in accordance with article 10(5), R&TTE Directive 1999/5/EC based on Following Annex III of the directive and LVD directive
2006/95/EC based on results using Harmonized standards.
This product meets the requirements of Class II, Grade 2 equipment as per EN50131-1: 2006+A1:2009, EN50131-3:2009, EN50131-6:2008
(Type A), EN50136-1-1:1997, EN50136-2-1, EN50136-2-3 (ATS2) Standards.
This device is suitable for use in systems with the following notification options.
A (use of two warning devices and internal dialer required
B (self-powered warning device and internal dialer required
C (use of DSC compatible alternate communicator in back-up or redundant mode)
D (use of DSC compatible alternate communicator with encryption enabled required.)
For EN50131 compliant installations only the intrusion portion of the alarm system has been investigated. Fire Alarm and Auxiliary (Medical) Alarm
functions were not included in the evaluation of this product under the requirements of the above mentioned standards.
Additional features implemented for EN 50131 Grade 2:
Fire alarm and CO alarm annunciation
Auxiliary (medical) alarm annunciation
Optional feature implemented for EN 50131 Grade 2:
Removal from mounting tamper detection for non wire-free components
Appendix 4: Regulatory Approvals
- 236 -
Non-police
response
zones
Allowed
Default:
Enabled
Must choose
zone type for
Required
application
Depends on
user phone
line
Required
Default:
Disabled
Default:
Disabled