With an audible alarm active, using the keyswitch when disarmed is the same as entering an access code at the keypad.
Activating this zone type during the first 30 seconds of a delayed fire alarm is the same as pressing a key at the keypad (the
90 second delay starts). If left in the open state, the system does not arm until the zone is restored and tripped again.
068
Momentary Keyswitch Disarm
Use with a keyswitch module. Activating and restoring this zone disarms the partition and silences alarms. Tampers or faults
do not disarm the zone.
Note: Do not use as a global zone.
069
Maintained Keyswitch Disarm
Used with a maintained keyswitch. Activating this zone disarms the partition.
Tampers or faults on this zone do not disarm the partition.
071
Doorbell Zone
This zone type sounds a chime through keypads on the partition when activated. No alarms are generated. Various chime
tones can be programmed. Disabling door chime on the partition also disables the chime on this zone.
Note: Do not use as a global zone.
072
Push to Set (Non CP-01 panels only)
Activating this zone starts an infinite exit delay when armed according to the methods described in the table below. To com-
plete the arming sequence, this zone must be activated and restored. Once done, the exit delay timer starts.
Arming Method
User Code
Keyswitch
Away Key
*0 Arm
*9 Arm
Stay Key
Night Key
Remote Access/SMS
DLS Arm
NAA Arming
Do not use exit delay termination with this zone type. Away arming with this zone bypassed prevents arming.
[002] Zone Attributes
Zone attributes are used to customize the operation of zones. When a zone type (section [001]) is programmed, the default
zone attribute is automatically assigned.
When programming attributes using LED/ICON keypads:
Ready light ON: Program attributes [1-8]
l
Ready light and Armed light ON: Program attribute [9-16] (press [1] for option 9, press [6] for option 14 etc.)
l
Press [9] to switch between attributes [1-8] and attributes [9-16].
l
Note: These attributes override default settings. Do NOT change fire zone attributes from their default settings.
[001]-[128] Select Zone
The attributes listed below can be enabled and disabled for each zone.
01
Bell Audible
ON: An alarm activates the siren.
OFF: Silent alarm.
Section 6: Programming
Infinite Exit Delay
Y
Y
Y
Y
N
N
N
-
N
N
- 75 -
Arming Mode
Away
Away
Away
Away
Stay
Stay
Night
Do Not Use
Away
Away