DSC HS2128 Reference Manual page 114

Powerseries neo alarm controller
Hide thumbs Also See for HS2128:
Table of Contents

Advertisement

Section 6: Programming
7 – Burglary Not Verified
When using Cross Zoning, this reporting code is sent if the cross zone timer is initiated by the first cross zone alarm, but is
not verified by a second alarm before the timer expires.
8 – Alarm Cancel
Sent when a valid access code is entered during the communications cancel window. The central station acknowledges can-
cellation by providing a keypad ringback.
[002] Miscellaneous Alarm 2
1 – Holdup Verified
Sent when the configured Holdup verified conditions have been met.
NA
Note: Not for use with UL/ULC listed installations.
[011] Priority Alarms 1
The reporting codes in this section are sent to the Alarm & Restore call direction group and apply to all system keypads.
1/2 – Keypad Fire Alarm-[F] Key Alarm/Restore
Sent when [F] Key alarms/restores occur.
3/4 – Keypad Medical Alarm-[M] Key Alarm/Restore
Sent when [M] Key alarms/restores occur. The keypad beeps 10 times when the medical alarm is successfully com-
municated to the alarm monitoring station.
5/6 – Keypad Panic Alarm-[P] Key Alarm/Restore
Sent when [P] Key alarms/restores occur.
7/8 – Auxiliary Input Alarm/ Restore
Sent when an alarm condition occurs/ is restored on PGM 2 (if configured as an input).
[021] Fire Alarms 1
3/4 – PGM 2 2-Wire Alarm/Restore
When PGM 2 is programmed as a 2-wire smoke alarm, this reporting code is sent when an alarm condition is detected and
when it is restored.
[101] Tamper Events
3/4 – Module Tamper/Restore
This reporting code is transmitted when a system module enters a tamper alarm state and uses the System Tamper Alarm
and Tamper Restore call direction.
5 – Keypad Lockout
Sent when a number of invalid access codes have been entered at a system keypad.
This reporting code is sent to the system Tamper Alarm & Tamper Restore call direction group.
7 – Remote Lockout
Sent when a number of invalid access codes have been entered through DLS or Integration. This reporting code is sent to
the system Tamper Alarm & Tamper Restore call direction group.
[201] Open/Close Events 1
1/2 – User Closing/Opening
This reporting code is transmitted when a user arms/disarms a partition and uses the Opening and Closing call direction.
5/6 – Special Closing/Opening
This reporting code is transmitted when a partition is closed/opened using quick arm ([*][0]), downloading, or Stay or Away
function keys without an access code. The Opening and Closing call direction group is used for this reporting code.
- 114 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hs2064Hs2032Hs2016-4Hs2016

Table of Contents