[711]-[714] Holiday Schedules
Use this section to program holiday schedules. During holiday schedules, other scheduled events do not occur. Enter sec-
tion 711 to 714 for holiday group 1 to 4.
Each of the four available holiday groups can have up to 99 holiday schedules programmed.
[001]-[099] Holiday Dates 1-99
Program holiday dates in the following format: MMDDYY
MM valid entries are 01 to 12
DD valid entries are 01 to 31
YY valid entries are 00 to 99
6.3.17 [802] Audio Verification Module Programming
This module provides 2-way audio communication between the central station and the occupants of the premises.
Note: For complete programming descriptions and worksheets, see the Audio Verification module installation manual.
6.3.18 Wireless Programming
[804] Wireless Programming
This programming section is used to enroll, program and delete wireless devices. Note that the HSM2HOSTx wireless trans-
ceiver or RF model keypad must be installed in order to enroll wireless devices.
[000] – Wireless Device Enrollment
To enroll a wireless device using this method, press and hold the Enroll button on the device for 2-5 seconds until the LED
illuminates then release the button. The alarm system automatically discovers the device and the keypad displays a con-
firmation message. The device ID, type and the next available zone number are displayed. Press [*] to accept or scroll to
another available zone number. Batteries must be installed in the wireless device in order to enroll.
Note: Ensure wireless signal strength is adequate before mounting the wireless device. See the instructions provided with
the wireless device for details.
Note: For complete wireless device programming descriptions and worksheets, see the HSM2Hostx wireless transceiver
installation manual.
[850] Cellular Signal Strength
This section is used to view both the cellular signal strength and the radio technology in use.
Table 6-3 : Cellular Technology
Display
GP
ED
HS
H+
CD
EV
5 bars indicate maximum signal strength. 0 bars indicate the communicator is not connected to the network.