6. Enter the 3-digit number corresponding to a word (see "Word Library" on page 221) or use the scroll keys [<][>] to view
words in the library.
7. Press [*] to select the word.
8. To add another word, repeat the above procedure from step 4.
9. To add a space, press the right scroll key [>].
10. To clear characters, select Clear to End or Clear Display from the Select Options menu.
11. To save the current label, press [#] to exit label programming.
[051] Zone Tamper Label
This label is displayed when a zone is tampered. The maximum label size is 14 x 1 ASCII characters.
[052] Zone Fault Label
This label is displayed when a zone is in fault. The maximum label size is 14 x 1 ASCII characters.
[064] CO Alarm Message
Use this section to program a custom label that is displayed on keypads during a carbon monoxide alarm. The maximum
label size is 14 x 2 characters.
[065] Fire Alarm Message
Use this section to program a custom label that is displayed on keypads during a fire alarm. The maximum label size is 14 x
2 characters.
[066] Fail To Arm Event Message
This message is displayed on all partition keypads if a user attempts to arm the system when it is not ready to arm. The mes-
sage clears after five seconds. The maximum label size is 16 x 2 characters.
[067] Alarm When Armed Event Message
This message is displayed if an alarm occurred while the system was armed. The message is displayed when the system is
disarmed and remains on the screen for 5 seconds. Following this, the zones that went into alarm are displayed. The max-
imum label size is 16 x 2 characters.
[100] System Label
Use this section to program a custom label for the security system. This label is used in the event buffer when system events
occur. The maximum label size is 14 x 1 characters.
[101]-[108] Partition 1-8 Labels
Use this section to program a name for each partition for display on partition keypads and event messages. The maximum
label size is 14 x 2 characters. See "Programming" on page 62 for specific instructions on how to program labels.
[201]-[208][001]-[004] Partition Command Output Labels
Use this section to program custom labels for command outputs. These labels are used with output activation events in the
event buffer. Enter subsection [201] to [208] to select partition 1 to 8, then enter subsection [001] to [004] to select command
output 1 to 4 label.
The maximum label size is 14 x 2 characters. See "Programming" on page 62 for specific instructions on how to program
labels.