Calibrate Ctrl - Printronix SL5000 User Manual

Rfid smart label and thermal printers
Hide thumbs Also See for SL5000:
Table of Contents

Advertisement

Chapter
3

CALIBRATE CTRL

CALIBRATE CTRL
CALIBRATE
CTRL
(from page 96)
Gap/Mark
Auto
1
Sensor
Calibrate
Disable*
Run Calibrate
Mark
Gap
Advanced Gap
Advanced Notch
Paper Out
Manual
1
Sensor
Calibrate
Run Calibrate
Reflective*
Transmissive
Gap Length
Cal in Peel
0.12 inches*
Disable*
0.05 to 1.00 inches
Enable
Notes:
* = Factory Default
Italicized items are available only when you enable Admin User (in the PRINTER CONTROL menu).
1
Gap/Mark Sensor and Paper Out Sensor work in conjunction, as shown below:
Table 6
When you select an
Paper Out Sensor
option in Gap/Mark
defaults to...
Sensor...
Disable
Reflective
Mark
Reflective
Gap
Reflective
Advanced Gap
Transmissive
Advanced Notch
Transmissive
If you change the Gap/Mark Sensor or Paper Out Sensor, you must recalibrate the media.
2
When Admin User is enabled (in the PRINTER CONTROL menu), you can change the unit value to millimeters:
Under the Units submenu (in the MEDIA CONTROL menu), enable the "In Millimeters" option.
3
When Gap/Mark Sensor = Disable, Gap, or Mark, the default is 12. When Gap/Mark Sensor = Advanced Gap or
Advanced Notch, the default is 20.
138
Media
Sensed
Profile
Distance
Print Profile
0.00 inches
Pwr Up
HeadClose
Action
Disable*
Disable*
Auto-Cal
Auto-Cal
Seek TOF
Seek TOF
Min Calib
Mode
Delta
3
012*
012 to 050
Gap/Mark
Thresh
2
171*
180*
000 to 255
000 to 255
Online
Action
Auto-Cal
Disable*
Disable*
Enable
Enable
Use Label
Threshold
Range
Length
Enable*
50%*
Disable
5% to 95%
Paper Out
Thresh
Gap
Windowing
Dynamic
Sensing
Disable
Enable*