Errors - Lexmark MX610 Service Manual

Machine type 7016-630, -67x
Hide thumbs Also See for MX610:
Table of Contents

Advertisement

950–958 errors
950–958 error messages
Error code
Description
950.xx
NVRAM mismatch failure—mismatch between
controller board EEPROM and control panel mirror.
".xx" codes:
00-29— mismatch between system and mirror
30-60—mismatch between secure and system
952.xx
A recoverable NVRAM Cyclic Redundancy Check (CRC)
error occurred—n is the offset at which the error
occurred.
953.xx
NVRAM chip failure with mirror part
Replace the controller board.
954.xx
NVRAM chip failure with system part
Replace the controller board.
955.xx
The Code ROM or NAND flash failed the Cyclic
Redundancy Check (CRC) or the NAND experienced an
uncorrectable multi-bit failure.
Replace the controller board.
956.xx
RIP card failure—processor failure
Replace the controller board.
956.01
Processor temperature is over the limit.
Replace the controller board.
957.xx
RIP card failure—ASIC failure
Replace the controller board.
958.xx
Controller Board NAND Failure—printer has
performed more than 100 shift and reflash operations
as a result of ECC bit corrections.
Replace the controller board.
NVRAM mismatch failure service check
Warning—Potential Damage: When replacing any of the following components:
Control panel assembly
Controller board assembly
Replace only one component at a time. Replace the required component and perform a POR before replacing a second
component listed above. If this procedure is not followed, the printer will be rendered inoperable. Never replace two
or more of the components listed above without a POR after installing each one or the printer will be rendered
inoperable.
Action
Go to
"NVRAM mismatch failure service check" on
page
135.
Go to
"NVRAM cyclic redundancy service check" on
page
136.
Go to
"Controller board removal" on page
Diagnostic information
135
7016
257.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xm3150

Table of Contents