Communication Connector - Unipulse F372A Operation Manual

Cc-link i/f
Hide thumbs Also See for F372A:
Table of Contents

Advertisement

4.Communication Connector

Measurement work selection:
Control input selection:
How to set
SET. →
Cautions
Settings of Mitsubishi (general-purpose) PLC CPU unit.
When you use Mitsubishi (general-purpose) PLC MELSEC-Q series, set up master
station network parameters as follows.
・CC-Link mode setting: Remote net Ver. 1 mode.
・Station type:
4.
Communication Connector
Each meaning of signal line represents each signal type as
follows: SLD and FG are connected inside.
Suitable plug for the connection is the plug made by WAGO
CO., Ltd. or equivalent one. (Accessories)
Name
DA
DB
DG
SLD
FG
Operating method
2
Select the method of specifying measurement work.
Select the method of specifying control (SECTION signal, T/H
signal, GRAPH TRIG signal) input.
Setting range: Communication
Initial value:
System Setting
Operation → Page 3
Remote device station
(Station information settings → Station type)
Signal Type
Signal line DA side
Signal line DB side
Signal line Ground
Shield
Frame Ground
Specifying by external input is disabled, and
specifying by CC-Link is enabled.
External input
Specifying by CC-Link is disabled, and
specifying by external input is enabled.
External input
- Pick up the plug and operate the lever with a
thumb.
- For the protection from the damage, do not
operate the lever without removing the plug.