Explanation For Remote Resister M → R - Unipulse F372A Operation Manual

Cc-link i/f
Hide thumbs Also See for F372A:
Table of Contents

Advertisement

■Explanation for remote resister M → R
◎Exclusive area (32bit BCD)
Use for writing into each set value by using request flag 1.
MSB
3
10
4bit
Sign
4bit
Set HH, HI, LO, LL and Near zero.
If each digit is set the value of which is larger than 9, it is handled by setting it as 9 is set.
Sign is indicated as follows:
  0:
Plus (+)
Minus (-)
  1:
◎General purpose area (32bit BCD)
Use for reading/writing of set values and control by using request flag 2.
MSB
3
10
4bit
Sign
4bit
If each digit is set the value of which is larger than 9, it is handled by setting it as 9 is set.
Sign is indicated as follows:
  0:
Plus (+)
Minus (-)
  1:
◎Command No. (16bit BCD)
Set a Command number. Be aware that the Request flag 2 does not respond to a invalid command.
MSB
3
10
4bit
◎Work No. (8bit BCD)
Set a Work number. Setting Value is set to this CODE.
MSB
0
4bit
2
1
10
10
4bit
0
0
4bit
2
1
10
10
4bit
0
0
4bit
2
1
10
10
4bit
1
0
10
4bit
LSB
0
10
4bit
4bit
4
10
4bit
4bit
LSB
0
10
4bit
4bit
4
10
4bit
4bit
LSB
0
10
4bit
4bit
LSB
0
10
4bit
4bit
7.Address Map