15
–
Select the menu item to be adjusted, then touch [Test Copy].
The Test Copy Screen will be displayed.
–
Press [Start] to make a sample copy. When completed, touch
[Close] to return to the Punch Resist Loop Size Screen.
–
Check the hole positions of the sample copy.
Touch [+] or [–] to change the adjustment value if satisfactory result
is not obtained.
Too much adjustment value may cause a fold at the end of paper.
–
Repeat this procedure until a satisfactory result is obtained.
7
Touch [OK] to complete the setting.
–
To cancel the change, touch [Cancel].
In either case, the Expert Adjustment Screen will be restored.
8
If further changes are required, touch the desired key.
15-58
Utility <Administrator Setting>