TEST NO. 7: Manifold Relief Valve Pressure (Using Tester With Pressure Gauges and
Flow Meter)
FROM REEL
DRIVE PUMP
MD1
FROM CARTRIDGE
VALVES AND LEFT
WHEEL MOTOR
Install tester in series
between
fitting
and
hose at the motor (right
hand motor shown).
Hydraulic System
G1
HYDRAULIC MANIFOLD
Page 4 – 32
TESTER
M2
RH
D1
M1
M5
CTR
D3
M6
M4
LH
D2
M3
Figure 27
TO COOLER
Working Pressure
Low Pressure (Charge)
Return or Suction
Flow
Reelmaster 2000–D