Hour Meter

1. Connect the positive (+) terminal of a 12 VDC source
to the positive (+) terminal of the hour meter.
2. Connect the negative (–) terminal of the voltage
source to the other terminal of the hour meter.
3. The hour meter should move a 1/10 of an hour in six
minutes.
4. Disconnect the voltage source from the hour meter.

Reels On Indicator Light

The reels on indicator light should illuminate when the
reels are engaged.
Testing Indicator Light
1. Apply 12 VDC to terminal 1A (Fig. 9).
2. Ground terminals 1B (Fig. 9).
3. Indicator light should illuminate.

Reel Engage Switch

The reel engage switch is mounted on the instrument
panel and is pulled to engage the cutting reels. The Re-
elmaster 2000–D uses only two of the six switch termi-
nals. When the switch knob is pulled, switch terminals
1 (COM C) and 4 should have continuity (Fig. 12). When
the switch knob is pushed in, switch terminals 1 (COM
C) and 4 should not have continuity.
The Standard Control Module monitors the operation of
the reel engage switch. If the ignition switch is in the ON
position and the reel engage switch is pulled, the Module
PTO switch input LED should be illuminated.
Reelmaster 2000–D
1
1. Terminal 1 (COM C)
Page 5 – 13
Hobbs
QUARTZ
1
0 0 0 0
1
10
HOURS
+
BACK
Figure 10
1B (–)
1A (+)
BACK OF LIGHT
Figure 11
1
2
Figure 12
2. Terminal 4