Installation
1. Inspect flanged bushings and bushing for wear; re-
place if necessary.
2. Clean and apply anti–seize lubricant to both bedbar
pivots. Install bedbar washer on the bedbar.
3. Install bedbar adjusting housing and bedbar housing
on the bedbar. Reinstall spacer, flat washer, lock wash-
er, and cap screw to the right end of the bedbar.
4. Position bedbar assembly to the cutting unit.
5. Secure bedbar housing to the cutting unit with both
carriage bolts and nuts.
6. Secure adjusting housing to the cutting unit with both
carriage bolts and nuts (Fig. 9).
7. Tighten both adjusting nuts on the adjusting housing
(Fig. 9).
8. Position bedbar fitting to the bedbar yoke. Screw ad-
justing handle (left–hand threaded) until the bedbar fit-
ting is snug against the bedbar yoke.
9. If weights were removed from bedbar (Models 03213
and 03214), apply permanent thread–locking com-
pound to cap screw threads and secure weights to bed-
bar with cap screws and lock nuts.
10.Adjust bedknife to reel (see Cutting Unit Operator's
Manual).
Reelmaster 2000–D
1. Adjusting lock nut
2. Adjusting nut
Page 7 – 11
2
3
4
Figure 9
3. Adjusting housing
4. Carriage bolt and nut