Figure 67. Removing Hot Swap Power Supply Module

5. Remove second (redundant) hot swap power supply module (or filler panel), if one is
present.
6. Disconnect all internal power cables from chassis components and server board.
7. Remove two internal screws (see letter "A" in the following figure) securing hot swap
power supply cage to chassis.

Figure 68. Detaching Hot Swap Power Supply Cage from Inside of Chassis

8. Remove five external screws securing back of power supply cage to chassis. Slide the
power supply cage out of the chassis.