Installing And Removing A Power Supply Module; Figure 16. Removing Backup Battery - Intel MFSYS25 User Manual

Modular server system
Hide thumbs Also See for MFSYS25:
Table of Contents

Advertisement

6. Disconnect the battery cable from the battery connector on the printed circuit board
(see letter "A" in the following figure). Remove the battery from the black plastic
battery holder (see letter "B").
7. Align notches in top cover with corresponding tabs in storage controller. Slide the top
cover forward to close.
8. Secure the top cover to the storage controller with the two screws previously
removed.
9. Re-install storage controller in server system. For instructions, see
Storage Controller" on page

Installing and Removing a Power Supply Module

The Intel
installed. A single power supply is suitable to support the power requirement for the
chassis, including fan modules, storage controller, switch module, storage bay, and a
single compute module. Additional power modules are required as the number of installed
compute modules increases.
Note: One power supply module will support one compute module plus all other modules in the
system.
Two power supply modules will support two to three compute modules (in any slot) plus
all other modules in the system.
Intel® Modular Server System MFSYS25 User Guide

Figure 16. Removing Backup Battery

®
Modular Server System MFSYS25 ships with two power supply modules pre-
B
19.
A
AF002461
"Installing a
25

Advertisement

Table of Contents
loading

Table of Contents