Hardware Installations and Upgrades
11. Reinstall the right side cover. Reinstall the two screws.
Warning: This chassis must be operated with the right side cover installed to ensure proper cooling.
Figure 52. Re-installing Right Side Cover on Chassis
12. Reinstall the front bezel assembly. For instructions, see
Assembly".
13. Reinstall the left side cover. For instructions, see
14. Reconnect all peripheral devices and the AC power cable. Power up the server.
Replacing a System Fan
Caution: The system fan for the Intel
removing or replacing a fan, you must first take the server out of service, turn off all
peripheral devices connected to the system, turn off the system by pressing the power
button, and unplug the AC power cord from the system or wall outlet.
1. Observe the safety and ESD precautions listed in
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the left side cover. For instructions, see
44
®
Server Chassis SC5650 is NOT hot swappable. Before
®
Intel
Chassis SC5650-DP/WS/BRP/UP Service Guide
TP01741
"Installing the Front Bezel
"Installing the Left Side Cover"
Appendix A, "Safety
"Removing the Left Side
Information".
Cover".