Download Print this page
Intel SC5650BRP - Server Chassis - Tower Quick Start User Manual
Intel SC5650BRP - Server Chassis - Tower Quick Start User Manual

Intel SC5650BRP - Server Chassis - Tower Quick Start User Manual

Server chassis
Hide thumbs Also See for SC5650BRP - Server Chassis - Tower:

Advertisement

Quick Links

Intel
Server Chassis
®
SC5650BRP/SC5650DP/
SC5650WS/SC5650UP
Quick Start User's Guide
Thank you for buying the Intel
Server Chassis SC5650.
®
The following information will help you to prepare your chassis
for integration with your selected Intel
®
Server Board.
These guides and other supporting documents (including
a list of supported server boards) are located on the web at
http://support.intel.com/support/motherboards/server/chassis/SC5650/
If you are not familiar with ESD (Electrostatic Discharge) procedures
used during system integration, please see the Intel
Server
®
Chassis SC5650 Service Guide, available on the CD that came with
your Intel® Server Board.
Read all cautions and warnings before starting your server chassis
integration.
3
Warning
Remove Tool-less Hard Drive Cage
Read all caution and safety
statements in this document
before performing any of the
instructions. Also see the Intel
®
Server Board and Server Chassis
Safety Information document at:
http://support.intel.com/support/
motherboards/server/sb/cs-010770
.htm
for complete safety information.
Warning
Installation and service of
this product to be performed
only by qualified service
personnel to avoid risk of injury from
electrical shock or energy hazard.
1
Loosen thumb screw. Apply pressure
to right side of EMI shield to release
Caution
EMI shield from hard drive cage.
Observe normal ESD
[Electrostatic Discharge]
procedures during system
integration to avoid possible
5
b
damage to server board and/or
other components.
Remove Fan Duct/System Fan
Tools Required
Assembly (for UP)
Hex nut driver
(0.25 in or
6 mm)
#2 Phillips*
Anti-static
screwdriver
wrist strap
Intel is a registered trademark of Intel Corporation or its
Snap-in
subsidiaries in the United States and other countries.
Bracket
*Other names and brands may be claimed as the
property of others. Copyright © 2009, Intel Corporation.
All rights reserved.
1
For SC5650UP only,
E39540-004
remove fan duct
assembly and system
fan by pushing the left
and right tabs outward
and disengaging from snap-in bracket.
4
2
Push blue plastic
release mechanism
upward to unlatch
hard drive cage.
2
2
1
3
3
Once released, pull hard drive
cage out of chassis.
6
7
Remove PCI Card Guide
(only for S5500BC)
See your Intel
1
Press in on two blue tabs.
installation instructions and installation of the back panel I/O shield.
2
Pull PCI card guide outward and remove
Use the mounting screws, bumpers and standoffs (if necessary) that came
from chassis.
with your chassis to secure the server board to the chassis.
1
2
For other configurations, see the Quick Start User's Guide that came
with your Intel
Return to this document when finished.
Building Value With Intel
Server Products, Programs and Support
Get the high-value server solutions you need by
Intel
taking advantage of the outstanding value Intel
for information about all of Intel's server
provides to system integrators:
building blocks, such as:
High-quality server building blocks
Extensive breadth of server building blocks
Solutions and tools to enable e-Business
Intel
®
System Management Software
Comprehensive training services
Worldwide 24x7 technical support
1
[AT&T Country Code + 866-655-6565]
World-class service, including a three-year
limited warranty and Advanced Warranty
Replacement
1
Intel® Server Board Guide
The server board that can be installed in your
Intel
Server Chassis SC5650 is dependent upon
®
the configuration of the chassis purchased.
Chassis Configuration
Compatible
Product Code
Intel
®
Server Board
S5500BC, S5520HC,
SC5650DP
S5500HCV
SC5650WS
S5520SC
S5500BC, S5520HC,
SC5650BRP
S5500HCV
SC5650UP
S3420GP Family
SC5650DP and SC5650BRP do not need a system air duct with S5500BC board.
Only SC5650WS can support 130 W TDP CPU.
Install Tool-less CD-ROM or DVD-ROM Drive
1
Remove EMI shield from 5.25-inch device drive bay.
2
Make sure latch is in "unlock" position.
3
Insert CD-ROM or DVD-ROM
drive into device drive bay.
2
4
Line up holes in CD-ROM
or DVD-ROM drive with
1
holes in chassis.
5
Move latch to "lock" position.
6
Connect power (P5 or P6 for
DP/BRP/WS; P3 or P4 for UP)
cables and data cables to rear
of the CD-ROM or DVD-ROM
drive.
An additional 4-pin IDE male-to-SATA 15 pin power cable
adapter may be needed if the CD-ROM or DVD-ROM does
not have a 4-pin power connector.
Data cables are included with the Intel
®
Server Board.
Chassis Fan Connection for the Intel
Install Server Board
= System Fan
header used
S5520HC/S5500HCV
®
server board Quick Start User's Guide for server board
S5520SC
System Fan 1
System Fan 2
System Fan 3
The standoffs that ship with the chassis need to be adjusted to
System Fan 4
accommodate the Intel
®
Server Board
assembled. For the Intel
®
System Fan 5
Server Board S5500BC, standoffs should be installed at the following
positions: K, L, M, F, 3, H, A and C. For the Intel
®
Server Board
S5520HC/S5500HCV/S5520SC, standoffs should be installed at the
following positions: K, L1, F, 3, E, J1, A, C and D, while there is a
push pin already installed at position N.
= Fan header used
System Fan 1
For the
Intel
®
Server Board S3420GP family, standoffs should be
installed at the following positions: 1,3,A,C,F,H,K,L and M.
System Fan 2
System Fan 3
®
Server Board.
1
Remove Side Cover
1
Remove two screws.
2
®
ServerBuilder is your one-stop shop
Push in latch.
3
Slide side cover
rearward and remove.
Product information, including product
briefs and technical product
specifications
Sales tools, such as videos and
presentations
Training information, such as the Intel
®
Online Learning Center
Support Information and much more
1
Available only to Intel
®
Channel Program
Members, part of the Intel
e-Business Network.
®
2
Remove Front Bezel Assembly
1
1
5
a
1
4
2
6
5
3
Server Boards S5520HC / S5500HCV and Intel
Workstation Board S5520SC
®
®
Intel
Server
Intel
Server
Intel
Server
®
®
®
Notes:
Chassis SC5650DP
Chassis SC5650BRP
Chassis SC5650WS
PCI Zone Chassis Fan
HDD Cage Fan
Rear Chassis Fan
Chassis Fan Connection for the Intel
Server Board S5500BC
Chassis Fan Connection for the Intel
®
Intel
®
Server
Intel
®
Server
Notes:
= Fan header used
Chassis SC5650DP
Chassis SC5650BRP
PCI Zone Chassis Fan
System Fan 1
HDD Cage Fan
System Fan 2
Rear Chassis Fan
System Fan 3
System Fan 4
1
2
3
1
3
1
Lift outward two bezel tabs on
left side of bezel assembly
to detach bezel assembly from
the chassis.
3
2
Rotate left side of front bezel
assembly outward slightly.
Disengage three bezel clips
3
that attach the right side
3
of the bezel to the right side of
the chassis and remove.
2
Remove Fan Duct/
System Fan Assembly
For SC5650 DP/BRP/WS only:
Remove fan duct assembly as shown.
Remove system fan by
pushing the right and
left tabs outward and
disengaging from
fan housing.
1
Right
Left
Tab
Tab
2
Server Board S3420GP Family
®
Intel
®
Server
Notes:
Chassis SC5650UP
HDD Cage Fan
Rear Chassis Fan

Advertisement

loading

This manual is also suitable for: