• Marriage: Marriage must be established to allow the projector to play encrypted content. This means the
security boundaries SPB1 and SPB2 are physically and electrically connected and that marriage is monitored
24/7. Marriage is initiated from a Wizard application on the TPC. A user with the appropriate credentials is
prompted to press the Marriage button to establish marriage. If the button is pressed any other time it is
ignored. Marriage cannot be established remotely.
• Emergency Start: This button is recessed into the faceplate to prevent accidental activation. It should only
be used when the TPC has failed or is disconnected. When pressed, the projector is powered on, the lamp is
powered up and the douser is opened. When you press and hold this button, the douser is closed and the lamp
is powered OFF, but power is still ON.
• Reset: This button is slightly recessed into the faceplate to prevent accidental activation. The main purpose
is to reset the electronics of the projector. After re-booting, the projector will return to the previous power
mode (STANDBY or FULL power), however the lamp will not strike automatically and requires manual
striking.
• DVI-A / DVI-B: Connect a variety of non-cinema video and graphics sources to either of these identical
single-link DVI ports. These are single-link ports for single-link cables/connectors only. The connectors can
be used together as a twin-link DVI port.
• HD-SDI A/HD-SDI-B: Connect a variety of high-definition cinema sources to these SMPTE 292M bit-
serial standard interface BNCs. The connectors can be used together to deliver Dual Link HD-SDI following
the SMPTE 372M standard.
PIB Faceplate Status Indicators
• STBY: Standby power (Single Color Green) indicates the presence of +24V from the standby power supply.
• OFF: Indicates no standby power (breaker OFF or Standby power failure).
• Green: Indicates standby power.
• PWR: Main power (Single Color Green) indicates the presence of +24V from the Low Voltage Power
Supply (LVPS).
• OFF: No LVPS power (STANDBY mode or breaker OFF).
• Green: Indicates full power.
• RUN: Blinking heartbeat (bi-color green/yellow).
• OFF or Solid Green: Indicates projector not functioning properly.
• Blinking Green: OK (software/communication/OS/ICP/Enigma/IMB if present are operating
normally).
• Solid Yellow: Communication error. NiOS functioning OK, but can no longer communicate with TPC.
• PIB: Projector Intelligence Board Status (Bi-color Red/Green)
• OFF: Not detected.
• Red: Detected communication problems etc.
• Blinking Red: PIB card seating error.
• Green: Detected and working properly.
• ICP: Integrated Cinema Processor Status (Bi-color Red/Green)
• OFF: Not detected.
• Red: Detected communication problems etc.
• Green: Detected and working properly.
• LD: Link Decrypter (Enigma) Status (Bi-color Red/Green)
• OFF: Not detected.
• Red: Detected communication problems etc.
• Green: Detected and working properly.
• IMB: Image Media Block Status (Bi-color Red/Green)