EXAMPLES:
(LHO 500 1) Move lens to position 500 along horizontal axis with positive approach
(LHO 500 -1) Move lens to position 500 along horizontal axis with negative approach
(LHO+C101 -500 1) Set lens horizontal position for channel 1 to -500 with positive approach
(LHO ?) Return current motor position along horizontal axis and direction (-1 or 1)
(LHO+CALB 1) Calibrate the horizontal axis
(LHO+RSET 1) Reset the horizontal axis
(LHO+STRT 1) Starts motor moving in positive direction
(LHO+STOP) Stops motor
(LHO+MOVR -100) Move motor 100 steps in negative direction
(LHO+MOVR 200) Move motor 200 steps in positive direction
Lamp ID (Type) (LID)
Get lamp type (ID) for the currently installed lamp. Supports readback of the list of supported lamp types.
SUBCODE
NONE
EXAMPLES:
(LID?L) List supported lamp IDs
(LID?) Get the lamp ID for installed lamp
LampLOC™ Module (LLM)
Allows adjustment of lamp position to optimize intensity and uniformity of the optical system. This is referred to
as the LampLOC™ feature and can be done automatically or manually.
SUBCODE
AUTO
CALI
MTRX
MTRY
MTRZ
NONE
STAT
EXAMPLES:
(LLM+MTRX 100) Move motor X to position 100
(LLM+AUTO 1) Do LampLOC™ automatically
(LLM+AUTO 0) Abort LampLOC™. It will restore the motors to previous position automatically
(LLM+AUTO?) Get running status. (LLM+AUTO!000) indicates finished, (LLM+AUTO!001) indicates running
(LLM+STAT ?) Get the progress feedback of the Auto mode (0-100%)
Adjust All Lens Position Parameters Simultaneously (LMV)
Adjust all lens position parameters simultaneously.
SUBCODE
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)
Downloaded from ProjectorsManual.com Manuals
DESCRIPTION OF USE
Get Lamp ID for current lamp. This is a read-only control. Lamp ID can be changed with LPC (lamp
change) command only.
DESCRIPTION OF USE
Set to 1 to do LampLOC™ automatically. It will do calibration first, then move the X, Y, Z-motors to find
the maximum brightness. Set to 0 to cancel auto adjustment and restore the previous position. Reset to 0
when it has finished.
Calibrate LampLOC motors.
Moving X-axis motor manually. Data range from ±250.
Moving Y-axis motor manually. Data range from ±250.
Moving Z-axis motor manually. Data range from ±175.
Not Available
Provides feedback (status) on the progress of the Auto mode. Read-only command. Data range from 0 to
100, where 100 indicates the LampLOC™ is finished.
DESCRIPTION OF USE