Appendix A: Serial API Commands
EXAMPLES:
(TMD+DSTA?) 0 or 1 (DST OFF or DST ON)
(TMD+DSTA 0) Turn daylight savings OFF (0) or ON (1)
(TMD+ZONE 20) Set time zone to EST
(TMD+TIME? ) Get local time (TMD+TIME! 17:50:45)
(TMD+TOFF 120) Increase the time by two minutes.
("TMD+TOFF: Disabled Control") Error message returned when power is OFF.
("TMD+TOFF: LD Real Time Clock Offset range for time adjustment has been exceeded.")
3D Output Reference Polarity (TOP)
Setup output timing signal reference polarity for 3D control.
SUBCODE
DESCRIPTION OF USE
Replace xxx with the channel number. Valid range is 101-164.
Cxxx
Select output reference polarity for the current channel.
NONE
EXAMPLES:
(TOP+C101 1) Set Output Reference Polarity to 1 on channel 101
(TOP+C101?) Get Output Reference Polarity on channel 101
User ID (UID)
Allows users to log in to the serial interface.
SUBCODE
DESCRIPTION OF USE
None
NONE
EXAMPLES:
(UID) "username" "password") Log in a user
(UID) Logout the current user, also happens automatically when a new user logs in
(UID?)(UID! "username" 01) Display the current logged in user and their access level
Zoom Lens Position Adjustment (ZOM)
Adjust lens to specific zoom position with a specified direction (1, -1). NOTE: This command can only be used to
update the current ILS file. Changing the zoom for the current channel will change the zoom for any channel using
the same ILS file.
Use command without subcode:
If ILS is ON, motor will move to specified steps and save data to the active channel.
If ILS is OFF, motor will move to specified steps, do not save data to the active channel.
SUBCODE
DESCRIPTION OF USE
Motor backlash in negative direction. Read-only.
BACN
Motor backlash in positive direction. Read-only.
BACP
Calibrate travel range and backlash on specified. Only valid parameter for this command is 1. Set only
CALB
command.
Replace xxx with the channel number. Valid range is 101-164.
Cxxx
Moving lens mount to a specified vertical position.
NONE
Motor moving range in negative direction. Read-only.
RNGN
Motor moving range in positive direction. Read-only.
RNGP
Move motor to the center flag then move back to current position. Only valid parameter for this command
RSET
is 1. Set only command.
A-24
Downloaded from ProjectorsManual.com Manuals
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)