Defaults (DEF)
This control will reset all preference and configuration settings in the device to their default values. The value of 111 must be
sent with each of the sub codes as well as the default. The number 111 helps prevent accidental use of this control. Select data
packing format for selected input.
SUBCODE
CHAN
CONF
PREF
UNSV
USER
NONE
EXAMPLES:
(DEF 111) Restore all preference, configuration, and user controls to default.
(DEF+USER 111) Clear all users and restore factory default user
(DEF+CONF 111) Reset all configuration controls
(DEF+PREF 111) Reset all preference controls
(DEF+CHAN 101) Restore Channel 101
(DEF+CHAN 0) Restore all channels
Data Logging (DLG)
Set/get the lowest log level to write to the engineering log, also extract data from log in text format.
Levels are:
0 =
Trace: Level test output, threading info, protocol.
1 = Debug: Debug messages.
2 = Info: Informational messages.
3 = Notices: Event of importance
4 = Warning: Warnings
5 = Error: An error has occurred
6 = Clear: An error has been cleared
SUBCODE
NONE
EXLG
EXAMPLES:
(DLG "20091108" "20091110" "ALL")
(DLG+EXLG!"Log data extracted to filename 'logextract.txt' on FTP root")
(DLG 2) Set current logging level to 2
(DLG?) Get current logging level. Response is (LDG!00002 "Info")
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)
Downloaded from ProjectorsManual.com Manuals
DESCRIPTION OF USE
Restore default channel settings for specified channel. 0 defaults all channels.
Restore default configuration settings.
Restore default preferences.
Restore unsaved controls.
Clears all users and restores the factory default user.
Restore channel, config, preferences, and users.
DESCRIPTION OF USE
Set/get the minimum log level to write to the log.
Extract entries from log files. Requires 3 parameters: "startdate", "enddate", "logtype". The data parame-
ters require the date in the format "yyyymmdd". The logtype parameter can have the following values:
"ENG" (engineering),
"SEC" (security),
"OPR" (operational),
"MAI" (maintenance),
"EVE" (event),
"SYS" (system),
"ALL".
Appendix A: Serial API Commands