Installation And Setup; Site Requirements; Physical Operating Environment; External Exhaust Ducting - Christie D4K2560 User Manual

Hfr 3-chip dlp 4k projector
Hide thumbs Also See for D4K2560:
Table of Contents

Advertisement

Installation and Setup

This section explains how to install, connect, and optimize the projector display.

Site requirements

To safely install and operate the projector, the installation location must have restricted access for
authorized personal only and meet these minimum requirements.

Physical operating environment

Maximum Ambient Temperature (operating) 35°C (95°F)
Minimum Ambient Temperature (operating) 10°C (50°F)

External exhaust ducting

The installation site must provide a minimum of 450 CFM (ft 3/min) external exhaust airflow to
ensure adequate cooling of the Xenon arc lamp at less than or equal to 25°C (77°F) ambient and
less than 3,000 ft (914.4 m) elevation. Above 25°C or 3,000 ft, 600 CFM is required.
For more details, see

Power connection

The requirements listed below are applicable for permanently wired installation or power cord
connection:
Terminal block, electrician hard-wired to the projector head.
Electrical rating: 200 - 240 VAC, 23 A max.
This product can be connected to an IT power distribution system.

Tools required for installation

12" screwdrivers: Phillips #2 (magnetic) and flat
19mm and 7/8" wrenches
Assorted Allen keys (metric)
D4K2560 User Manual
020-101076-04 Rev. 1 (01-2015)
Connect external exhaust ducting
on page 27.
20

Advertisement

Table of Contents
loading

Table of Contents