Christie D4K2560 User Manual page 25

Hfr 3-chip dlp 4k projector
Hide thumbs Also See for D4K2560:
Table of Contents

Advertisement

3. Connect to the terminal block.
i
Always connect the ground lead first to reduce shock hazard.
If connecting to permanent power, connect the AC power
source to the terminal block, beginning with the ground
lead.
If connecting to a pluggable type-B cable, connect the cable
to the terminal block, beginning with the ground lead.
Use an appropriately sized strain relief connector with the knockout plate provided to
ensure adequate environmental sealing and to prevent the cables from wear and
accidentally being torn out.
4. Reinstall the knockout plate and secure it with four screws.
5. Reinstall the bottom access panel over the terminal block and secure it with two screws.
If using a pluggable type-B cable, connect to the building's AC power source.
D4K2560 User Manual
020-101076-04 Rev. 1 (01-2015)
The terminal block accommodates up to an eight
AWG wire. If required, use a 90° strain relief
connector to route the power cable in a downward
direction.
Installation and Setup
3
25