Calling up

Calling up information

You can call up current temperatures, set values, time
programs and operating states.
The extended menu splits the information into groups:
"System"
"Heating circuit 1"
"Heating circuit 2"
"Heating circuit 3"
"Cooling circuit SKK"
"DHW"
"Ventilation"
"Solar"
"Heat pump"
"Daily log" (see page 40)
Calling up the solar energy yield
Only in connection with a solar control unit integrated
into the heat pump control unit.
Advanced menu
1.
2. "Solar energy"
The solar energy yield is shown in the form of a dia-
gram.
The flashing line on the graph indicates that the cur-
rent day is not yet over.
Daily log
The daily log lists the following information for each
calendar week ("CW") in tabular form:
"T.in"
Average primary temperature on entry into the
heat pump
"T.out" Average primary temperature at the outlet of
the heat pump
"HP1" Hours run, heat pump stage 1
"HP2" Hours run, heat pump stage 2
"AC"
Hours run in active cooling mode
"NC"
Hours run in natural cooling function
Note
This information will be retained even if the heat pump
control unit develops a fault.
Screed drying
Your heating contractor can, for example, enable the
"Screed drying" function for your new installation or
extension for screed drying. The screed will be dried in
line with a set time program suitable for the building
material (temperature:time profile).
40
Detailed call-up options for the individual groups can
be found in chapter "Extended menu overview" see
(page 54).
Note
If heating/cooling circuits have been named (see chap-
ter "Names for heating circuits"), the allocated name
will be displayed.
Extended menu
1.
2. "Information"
3. Select the category.
4. Select the information you wish to call up.
Solar energy
4.0
0
We
Th
Fr
Sa Su Mo Tu
kWh
Su 03.10.10
Select with
Fig. 33
Note
In conjunction with an external solar control unit (e.g.
Vitosolic 200), you can call up the solar energy yield
there.
Daily log
CW T.in
T.out HP1
HP2
12
7.2
4.3
123
37
13
7.8
4.7
113
21
14
7.5
4.5
103
15
15
7.0
3.3
93
9
16
6.9
3.1
97
10
17
6.8
3.0
89
28
18
7.2
4.4
133
45
Select with
Fig. 34
Advanced menu
1.
2. "Information"
3. "Daily log"
We
1.3
AC
NC
0
15
0
12
4
18
0
10
0
11
2
12
0
5
(