Energy Saving Function "Economy Mode - Viessmann VITOTRONIC 200 Operating Instructions Manual

Heating system and domestic ventilation system with heat pump control unit vitotronic 200, type wo1c
Table of Contents

Advertisement

Central heating/central cooling

Energy saving function "Economy mode"

Setting "Economy mode" for heating
Extended menu
1.
2. "Heating" or "Heating/cooling"
3. If necessary, / for the required heating/cooling cir-
cuit.
4. "Economy mode"
Display in the standard menu
21°C
14°C
Flow temperature
Fig. 20
Ending "Economy mode"
Automatically on changeover to the "Reduced" or
"Standby" operating status, depending on the time
program.
or
Set "Economy mode" to "OFF".
Energy saving function "Holiday program"
Setting the "Holiday program" for heating/cooling, ventilation
Note
The holiday program applies to all heating/cooling
circuits.
If a ventilation unit is connected to the heat pump
control unit, the holiday program also applies to the
domestic ventilation system.
The holiday program starts at 00:00 h on the day fol-
lowing your departure and ends at 00:00 h on the day
of your return. This means the selected time program
is active on the days of departure and return (see
page 21).
Extended menu:
1.
2. "Heating" or "Heating/cooling"
24
HC1
40°C
Note
The display of the set room temperature does not
change.
In "Economy mode", cooling via a heating/cooling
circuit is switched OFF.
"Economy mode" cannot be set for a separate
cooling circuit.
3. "Holiday program"
4. Set the required leaving and return dates.
Holiday program
Leaving date:
Date
We 13/06/2012
Return date:
Date
Fr 15/06/2012
Select with
Fig. 21
The holiday program has the following effects:
Central heating:
For heating/cooling circuits in the operating pro-
gram "Heating and DHW" or "Heating/cooling
and DHW":
The rooms are heated to the selected reduced
room temperature (see page 20).
For heating/cooling circuits in the operating pro-
gram "Only DHW":
No central heating; frost protection for the heat
pump and any heating water buffer cylinder instal-
led is active.
HC1
(