Operating Programs For Ventilation - Viessmann VITOTRONIC 200 Operating Instructions Manual

Heating system and domestic ventilation system with heat pump control unit vitotronic 200, type wo1c
Table of Contents

Advertisement

Operating program

Operating programs for ventilation

Operating program
"Standby mode"
"Standard operation"
"Ventilation program"
Special operating programs
Display in the standard menu
21 °C
14 °C
Screed drying
Flow temperature
E
Fig. 9
Special operating programs
"Screed drying"
This function is activated by your heating contractor.
Your screed is dried in line with a set time program
suitable for the building material (temperature:time
profile). Your settings for central heating/central cool-
ing have no effect for the duration of screed drying.
"External hook-up"
Your heat pump control unit is regulated by a higher
ranking control unit.
Time program
The following explains how to input the settings for a
time program. The special features of each individual
time program are assigned to the relevant chapters.
You can set up a time program for the following func-
tions:
Central heating/central cooling (see page 21)
Heating the heating water buffer cylinder (see
page 21)
DHW heating (see page 26)
DHW circulation pump (see page 27)
Electric booster heater (see page 29)
Quieter operation of air/water heat pumps (see
page 31)
Domestic ventilation (in conjunction with a ventilation
unit, see page 33)
(cont.)
Operating status
"Reduced"
"Standard"
"Intensive"
HC1
40 °C
:
E
Air flow rate
No ventilation
Minimum air flow rate
Reduced air flow rate
Standard air flow rate
Maximum air flow rate
"External program"
The operating program was changed by a communi-
cations interface (e.g. Vitocom 100).
"Holiday program"
See page 24.
Note
In the extended menu, you can call up the set operat-
ing program under "Information" (see page 40).
In the time program, divide the day into sections.
These are called time phases. It is for you to decide
what happens in these time phases. For example, they
could specify when your rooms will be heated to stand-
ard room temperature. To do this, you will need to set
an operating status.
You can set the time program individually, to be the
same for every day of the week or different.
You can select up to 8 time phases per day.
For each time phase you select the start and end
points.
The selected time phase is illustrated by a white bar
on the time chart. The length of the bar reflects the
length of time.
About the controls
Ventilation
stage
0
1
2
3
4
15