4.5.2 SIP Settings [Line 1]–[Line x]
Value Range
Default Value
Configuration File Reference

Timer B

Description
Value Range
Default Value
Configuration File Reference

Timer D

Description
Value Range
Default Value
Configuration File Reference

Timer F

Description
Value Range
Default Value
Configuration File Reference

Timer H

Description
Value Range
Default Value
Configuration File Reference
112
Administrator Guide
2
4
8
16
32
4
SIP_TIMER_T2_n (Page 253)
Specifies the value of SIP timer B (INVITE transaction timeout timer),
in milliseconds. For details, refer to RFC 3261.
250–64000
32000
SIP_TIMER_B_n (Page 265)
Specifies the value of SIP timer D (wait time for answer resending), in
milliseconds. For details, refer to RFC 3261.
0, 250–64000
5000
SIP_TIMER_D_n (Page 265)
Specifies the value of SIP timer F (non-INVITE transaction timeout
timer), in milliseconds. For details, refer to RFC 3261.
250–64000
32000
SIP_TIMER_F_n (Page 266)
Specifies the value of SIP timer H (wait time for ACK reception), in
milliseconds. For details, refer to RFC 3261.
250–64000
32000
SIP_TIMER_H_n (Page 266)