5.7.2 SIP Settings
Value Format
Description
Value Range
Default Value
Web User Interface Reference

SIP_TIMER_F_n

Parameter Name Example
Value Format
Description
Value Range
Default Value
Web User Interface Reference

SIP_TIMER_H_n

Parameter Name Example
Value Format
Description
Value Range
Default Value
Web User Interface Reference

SIP_TIMER_J_n

Parameter Name Example
Value Format
Description
Value Range
Default Value
Web User Interface Reference
266
Administrator Guide
Integer
Specifies the value of SIP timer D (wait time for answer resending), in
milliseconds. For details, refer to RFC 3261.
0, 250–64000
5000
Timer D (Page 112)
SIP_TIMER_F_1, SIP_TIMER_F_2, ..., SIP_TIMER_F_6
Integer
Specifies the value of SIP timer F (non-INVITE transaction timeout
timer), in milliseconds. For details, refer to RFC 3261.
250–64000
32000
Timer F (Page 112)
SIP_TIMER_H_1, SIP_TIMER_H_2, ..., SIP_TIMER_H_6
Integer
Specifies the value of SIP timer H (wait time for ACK reception), in
milliseconds. For details, refer to RFC 3261.
250–64000
32000
Timer H (Page 112)
SIP_TIMER_J_1, SIP_TIMER_J_2, ..., SIP_TIMER_J_6
Integer
Specifies the value of SIP timer J (wait time for non-INVITE request
resending), in milliseconds. For details, refer to RFC 3261.
0, 250–64000
5000
Timer J (Page 113)