Sip Service Domain; Service Domain; Sip Source Port; Source Port - Panasonic KX-UT123 Administrator's Manual

Hide thumbs Also See for KX-UT123:
Table of Contents

Advertisement

4.5.2.4 SIP Service Domain

Service Domain

Description
Value Range
Default Value
Configuration File Reference

4.5.2.5 SIP Source Port

Source Port

Description
Value Range
Default Value
Configuration File Reference

4.5.2.6 SIP Authentication

Authentication ID

Description
Value Range
Default Value
Document Version 2013-03
Specifies the domain name provided by your phone system dealer. The
domain name is the part of the SIP URI that comes after the "@" symbol.
Max. 127 characters
Not stored.
SIP_SVCDOMAIN_n (Page 250)
Specifies the source port number used by the unit for SIP
communication.
1024–49151
Note
You cannot specify here the same port number as any of the
port numbers in [Channel 1–25] in 4.3.6.3 External RTP
Port (if they are configured). In addition, you cannot specify a
port number that is 1 greater than a port number specified in
[Channel 1–25].
The available channel number varies depending on the type of
the unit being used.
The SIP port number for each line must be unique.
You cannot specify the same port number as the port number
specified in [Web Server Port] in 4.4.4.1 Web Server
Settings.
5060 (for Line 1)
5070 (for Line 2)
5080 (for Line 3)
5090 (for Line 4)
5100 (for Line 5)
5110 (for Line 6)
SIP_SRC_PORT_n (Page 249)
Specifies the authentication ID required to access the SIP server.
Max. 127 characters (except ", &, ', :, <, >, and space)
Not stored.
4.5.2 SIP Settings [Line 1]–[Line x]