4.6.4 Tone Settings
Tone Timings
Description
Value Range
Default Value
Configuration File Reference
4.6.4.3 Ringing Tone
Tone Frequencies
Description
Value Range
Default Value
Configuration File Reference
Tone Timings
Description
Value Range
Default Value
Configuration File Reference
138
Administrator Guide
Specifies the pattern, in milliseconds, of busy tones using up to 10
whole numbers (off 1, on 1, off 2, on 2...) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
0–16000 (0: Infinite time)
Note
•
Avoid setting 1–50 for any of the values.
60,500,440
BUSY_TONE_TIMING (Page 215)
Specifies the dual-tone frequencies, in hertz, of ringback tones using 2
whole numbers separated by a comma.
0, 200–2000 (0: No tone)
440,480
RINGBACK_TONE_FRQ (Page 216)
Specifies the pattern, in milliseconds, of ringback tones using up to 10
whole numbers (off 1, on 1, off 2, on 2...) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
0–16000 (0: Infinite time)
Note
•
Avoid setting 1–50 for any of the values.
60,2000,3940
RINGBACK_TONE_TIMING (Page 217)
Document Version 2013-03