Installation
Failure to comply with the following results in death or serious injury.
• This product must be installed within a restricted access location which is normally
• The installation setup must prevent access to the nominal ocular hazard area. See
Prepare the installation site
1. Clear the installation area.
2. Post laser hazard warning signs at all entry doors.
3. Place each component near its installation location.
Tools required
•
12 in. screwdrivers: Phillips #2 (magnetic) and flat
•
2.5mm, 3mm, and 5mm hex drivers
•
Adjustable wrench
•
Step stool
•
Powder-free N-DEX gloves
•
Clean dry air (CDA)
•
Isopropyl alcohol
•
cotton swabs
•
Fiber optic microscope (for example, THORLABS FS200)
Site requirements
This section lists the requirements for a successful installation.
Physical environment
Do not install any portion of the fiber bundle next to a heat source. Failure to comply may
result in equipment damage.
These requirements apply to all Christie Laser Projection System components.
•
Maximum ambient temperature (operating): 25 °C (95 °F)
D4KLH60/Mirage 4KLH Installation Guide
020-101374-01 Rev. 1 (05-2014)
inaccessible by the general public, including workers, visitors and residents in the
immediate vicinity, by means of engineering or administrative control measures but is
accessible to authorized personnel that may not have specific safety training.
Nominal ocular hazard distance
on page 75.
24