Basler A500k User Manual page 33

Area scan cameras
Hide thumbs Also See for A500k:
Table of Contents

Advertisement

Port
Camera
Port G0
Port G1
Port G2
Port G3
Port G4
Port G5
Port G6
Port G7
Port H0
Port H1
Port H2
Port H3
Port H4
Port H5
Port H6
Port H7
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
LVAL
FVAL
DVAL
Not Used
PClk
TxCLKIn
Table 2-9: Bit Assignments of the Channel Link Transmitter Z for the A503
k
Basler A500
PRELIMINARY
Plug No. 2, Transmitter Z
Frame Grabber
TxIN0
RxOUT0
TxIN1
RxOUT1
TxIN2
RxOUT2
TxIN3
RxOUT3
TxIN4
RxOUT4
TxIN6
RxOUT6
TxIN27
RxOUT27
TxIN5
RxOUT5
TxIN7
RxOUT7
TxIN8
RxOUT8
TxIN9
RxOUT9
TxIN12
RxOUT12
TxIN13
RxOUT13
TxIN14
RxOUT14
TxIN10
RxOUT10
TxIN11
RxOUT11
TxIN15
RxOUT15
TxIN18
RxOUT18
TxIN19
RxOUT19
TxIN20
RxOUT20
TxIN21
RxOUT21
TxIN22
RxOUT22
TxIN16
RxOUT16
TxIN17
RxOUT17
TxIN24
RxOUT24
TxIN25
RxOUT25
TxIN26
RxOUT26
TxIN23
RxOUT23
RxCLKOut
Signal
D6 Bit 0
D6 Bit 1
D6 Bit 2
D6 Bit 3
D6 Bit 4
D6 Bit 5
D6 Bit 6
D6 Bit 7 (MSB)
D7 Bit 0
D7 Bit 1
D7 Bit 2
D7 Bit 3
D7 Bit 4
D7 Bit 5
D7 Bit 6
D7 Bit 7 (MSB)
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Line Valid
Frame Valid
Line Valid
Not Used
Pixel Clock
Camera Interface
(Plug 2)
k
2-19