Commands For Manipulating Configuration Sets; Copy The Factory Set Or The User Set Into The Work Set (Profile Load) - Basler A500k User Manual

Area scan cameras
Hide thumbs Also See for A500k:
Table of Contents

Advertisement

4.2.7 Commands for Manipulating Configuration Sets

4.2.7.1 Copy the Factory Set or the User Set into the Work Set
(Profile Load)
Purpose:
To copy the Factory Set or one of the 15 User Sets into the Work Set. See section
explanation of configuration sets.
The write command will cause the selected set to be copied into the Work Set and the set
will become active immediately. Write commands greater than 0x0F will be ignored.
The read command returns the ID of the set that was last copied into the Work Set. (If nothing
has been copied to the Work Set since the last power up or reset, the read command will
return the ID for "no active set." This condition indicates that no valid Factory Set or User Sets
were found. It will also cause the orange LED on the back of the camera to flash six times.)
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
k
Basler A500
PRELIMINARY
Cmd-ID
R/W-Flag
0x45
1
Cmd-ID
R/W-Flag
0x45
0
Cmd-ID
R/W-Flag
0x45
0
None
Byte 1
An ID that specifies the set
(see table below).
Set ID
Set
0x00
Factory Set
0x01
User Set 1
0x02
User Set 2
0x03
User Set 3
0x04
User Set 4
0x05
User Set 5
0x06
User Set 6
0x07
User Set 7
0x08
User Set 8
0x09
User Set 9
0x0A
User Set 10
0x0B
User Set 11
0x0C
User Set 12
0x0D
User Set 13
0x0E
User Set 14
0x0F
User Set 15
0xFF
No active set