Read Serial Number; Read Camera Version; Read Eeprom Firmware Version - Basler A500k User Manual

Area scan cameras
Hide thumbs Also See for A500k:
Table of Contents

Advertisement

4.2.6.4 Read Serial Number

Purpose:
To read the camera's serial number.
Type:
This is a read only command.
Read Command:
Response:
Data Format:

4.2.6.5 Read Camera Version

Purpose:
To read the camera version information.
Type:
This is a read only command.
Read Command:
Response:
Data Format:

4.2.6.6 Read EEPROM Firmware Version

Purpose:
To read the EEPROM firmware version information.
Type:
This is a read only command.
Read Command:
Response:
Data Format:
k
Basler A500
PRELIMINARY
Cmd-ID
R/W-Flag
0x04
1
Cmd-ID
R/W-Flag
0x04
0
Zero terminated string if less than 16 bytes are needed for the serial number
information. Unterminated string if all 16 bytes are needed.
Cmd-ID
R/W-Flag
0x05
1
Cmd-ID
R/W-Flag
0x05
0
Byte 1
Low Byte of firmware version
Byte 2
High Byte of firmware version
Byte 3
Register Layout ID
Cmd-ID
R/W-Flag
0x06
1
Cmd-ID
R/W-Flag
0x06
0
Byte 1
Low byte of firmware version
Byte 2
High byte of firmware version
Byte 3
Register Layout ID
Configuring the Camera
Data Length
Data
16
Data Length
Data
16
16 Bytes
Data Length
Data
3
Data Length
Data
3
3 Bytes
BCD coded
BCD coded
Data Length
Data
3
Data Length
Data
3
3 Bytes
BCD coded
BCD coded
-
-
-