4.2.4.15 Area of Interest Stamp and Dynamic Area of Interest (A504k,

A503k Only)

Purpose:
To activate or deactivate the Area of Interest Stamp and Dynamic Area of Interest or to read
the settings. See sections
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
k
Basler A500
PRELIMINARY
3.10.3
and
3.10.2
Cmd-ID
R/W-Flag
0x99
1
Cmd-ID
R/W-Flag
0x99
0
Cmd-ID
R/W-Flag
0x99
0
None
Byte 1
An ID that specifies whether AOI Stamp and Dynamic AOI are
acivated or deactivated (see the table below).
ID
Setting
0x00
AOI Stamp and Dynamic AOI deacti-
vated (standard mode)
0x40
AOI Stamp deactivated and Dynamic
AOI activated
0x80
AOI Stamp activated and Dynamic AOI
deactivated
0xC0
AOI Stamp and Dynamic AOI activated
Configuring the Camera
for details.
Data Length
1
Data Length
1
Data Length
1
Data
-
Data
1 Byte
Data
1 Byte
4-21