Flashctrl: Flash Trigger Modes - Basler A500k User Manual

Area scan cameras
Hide thumbs Also See for A500k:
Table of Contents

Advertisement

Configuring the Camera

4.2.4.16 FlashCtrl: Flash Trigger Modes

Purpose:
To set the flash trigger mode or to read the current flash trigger mode setting. See sections
2.1.4
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
4-22
PRELIMINARY
and
for an explanation of flash trigger modes.
2.5.8
Cmd-ID
0xAC
Cmd-ID
0xAC
Cmd-ID
0xAC
None
Byte 1
ID
Flash Trigger Mode (standard TTL, push/pull driver)
0x00
The FlashOut signal is always low.
0x01
The FlashOut signal is high while the in-
ternal Integrate Enabled signal is high.
0x02
The FlashOut signal is high while the
ExFlash signal from the frame grabber
is high.
0x03
The FlashOut signal is always high.
0x05
The FlashOut signal is low while the in-
ternal Integrate Enabled signal is high.
0x06
The FlashOut signal is low while the
ExFlash signal from the frame grabber
is high.
ID
Advanced modes to combine with the upper modes
0x10
Open collector or Low Side Switch, 5 V max
0x20
High Side Switch 5 V
To combine an advanced mode with a
flash trigger mode, add the hexadecimal
number of the advanced code and the
one of the flash trigger mode together.
You can not select Low Side Switch and
High Side Switch at the same time.
R/W-Flag
Data Length
1
1
R/W-Flag
Data Length
0
1
R/W-Flag
Data Length
0
1
An ID that specifies the flash control mode
(see the table below).
Data
-
Data
1 Byte
Data
1 Byte
k