Basler A500k User Manual page 26

Area scan cameras
Hide thumbs Also See for A500k:
Table of Contents

Advertisement

Camera Interface
DS90CR287 - Transmitter X
Port A0
Tx0
Port A1
Tx1
Port A2
Tx2
Port A3
Tx3
Port A4
Tx4
Port A6
Tx6
Port A7
Tx7
Port B0
Tx8
Port B1
Tx9
Port B4
Tx12
Port B5
Tx13
Port B6
Tx14
Port B7
Tx15
Port C2
Tx18
Port C3
Tx19
Port C4
Tx20
Port C5
Tx21
Port C6
Tx22
LVAL
Tx24
FVAL
Tx25
Not Used
Tx26
Not Used
Tx27
Port A5
Tx5
Port B2
Tx10
Port B3
Tx11
Port C0
Tx16
Port C1
Tx17
Port C7
Tx23
Strobe
TxCLKIn
(PClk)
Flash Trigger
Reserved
ExSync
SerTC
DS90LV048A Rcvr.
SerTFG
DS90LV047A Tmtr.
Ferrite
Bead
Gnd
Not Connected
Not Connected
A501
k
Figure 2-7: A501
2-12
PRELIMINARY
15
X0+
15
2
2
X0-
16
16
X1+
3
3
X1-
17
17
X2+
4
4
X2-
19
19
X3+
6
6
X3-
18
Xclk+
18
5
5
Xclk-
CC3+
24
24
CC3-
11
11
12
12
25
25
CC2+
10
10
CC2-
23
23
CC1+
22
22
CC1-
9
9
7
SerTC+
7
SerTC-
20
20
21
21
SerTFG+
8
8
SerTFG-
1
1
13
13
14
14
26
26
12 V In
1
2
3
4
5
EMI
6
Filter
Gnd
Camera/Frame Grabber Interface
k
MDR Cable
Pair 1+
12
12
Pair 1-
25
25
11
11
Pair 2+
Pair 2-
24
24
Pair 3+
10
10
Pair 3-
23
23
Pair 5+
8
8
Pair 5-
21
21
9
Pair 4+
9
22
Pair 4-
22
Pair 10+
3
3
Pair 10-
16
16
Pair 11+
15
15
Pair 11-
2
2
Pair 9+
17
17
Pair 9-
4
4
Pair 8+
5
5
Pair 8-
18
18
Pair 6+
20
20
Pair 6-
7
7
Pair 7+
6
6
Pair 7-
19
19
Inner Shield
1
1
Inner Shield
13
13
Inner Shield
14
14
Inner Shield
26
26
26-pin Male
MDR Connector
26-pin Female
MDR Connector
DS90CR288A - Receiver X
Port A0
Rx0
Port A1
Rx1
X0+
Port A2
Rx2
Port A3
Rx3
X0-
Port A4
Rx4
Port A6
Rx6
Port A7
Rx7
Port B0
Rx8
Port B1
Rx9
X1+
Port B4
Rx12
Port B5
Rx13
X1-
Port B6
Rx14
Port B7
Rx15
Port C2
Rx18
Port C3
Rx19
Port C4
Rx20
X2+
Port C5
Rx21
Port C6
Rx22
X2-
LVAL
Rx24
FVAL
Rx25
Not Used
Rx26
Not Used
Rx27
Port A5
Rx5
X3+
Port B2
Rx10
Port B3
Rx11
X3-
Port C0
Rx16
Port C1
Rx17
Port C7
Rx23
Xclk+
Strobe
RxCLKOut
(PClk)
Xclk-
CC3+
Flash Trigger
CC3-
CC4+
Reserved
CC4-
CC2+
Reserved
CC2-
CC1+
ExSync
CC1-
SerTC+
SerTC
SerTC-
DS90LV047A Tmtr.
SerTFG+
SerTFG
SerTFG-
DS90LV048A Rcvr.
R1
Note: R1 should be
zero ohm. C1 is optional.
R1 and C1 can be used
to prevent ground loops
C1
if needed.