5.4 Mechanical Stress Test Results

Cameras were submitted to an independent mechanical testing laboratory and subjected to the
stress tests listed below. The mechanical stress tests were performed on selected camera models
with standard housings. After mechanical testing, the cameras exhibited no detectable physical
damage and produced normal images during standard operational testing.
Test
Vibration
(sinusoidal,
each axis)
Shock
(each axis)
Bump
(each axis)
Table 5-1: Mechanical Stress Tests
k
Basler A500
PRELIMINARY
Standard
Conditions
DIN IEC 60068-2-6
5-8.5 Hz / 1.5 mm_8.5-150 Hz /
10 m/s
5 repetitions (00:25 h test period)
DIN IEC 60068-2-27
C 11 ms / 3 shocks / positive
100 m/s
DIN IEC 60068-29
100 m/s
100 m/s
Mechanical Considerations
2
_1 Octave/Minute
2
11 ms / 3 shocks / negative
2
11 ms / 100 shocks / positive
2
11 ms / 100 shocks / negative
5-5