5.2.5 New SSSWs/parameters added to this model
SW01 (service soft switch 01: error management)
Function
Service error code
0
Error dump list
Not used
2
3
Copy function
4
5
Not used
Date & Time setting restriction
6
7
Not used
Even when Bit0 is set to "Not output", you can select whether or not to output ##300
series Service Error Codes, caused by hardware malfunction.
When "Output" is selected, ##300 series Service Error Codes are displayed and in
reports.
When "Not Output" is selected, no Service Error Codes are displayed.
TO Timer
11
Maximum time to receive
13
one line of image data
[Parameter 101
The "wait time after transmission of a dialing signal ends until a significant signal is
detected in transmission" was set as Tl timer with parameter 10.
However, ITU-T recommends that it should be set as TO timer, so parameter 10 has
been renamed to TO timer and the dcfwlt time-out time has been changed from 35 to
55 seconds.
The Tl timer for the transmitter (wait time after a CED, V21 flag, or
detected) is fixed at 35 seconds.
NOTE
[Parameter Ill
Set the Tl timer for the receiver (wait time after DIS transmission starts until a
significant signal is received).
If frequent errors occur during reception (2 instances) because of line connection
conditions, raise the value of this parameter.
[Parameter 131
Set the maximum time to receive one line of image data when image data is received.
If the other party is R computer fax and the time to receive one line of image data is
long, raise the wlue of this parameter to increase the maximum reception (2 instances)
time.
Chapter 3: Maintenance & Service
output
output
No
output
Setting restricted
Selecting range
o-9999
o-9999
500-3000
3-41
0
Not output
Not output
Yes
Not output
Setting possible
Default setting
5500 (55 second)
3500 (35 second)
1300 (13 second)