Error Codes - Formax 6600 Series Operator's Manual

Folder/inserters
Table of Contents

Advertisement

10.4

Error codes

error description
To many sheets in set.
Reading error.
Reading error.
Reading stop.
Reading error.
Reading error.
Reading error.
Reading error.
Service assistance is needed for the error codes with the message "technical failure". First write down
the error code, than switch the inserter off and on again, to verify system operation. When the error still
occurs contact your service organization.
46
suggested solution
Remove the documents and
complete the set manually.
Remove the documents and
complete the diverted set
manually. Occurs when the
reading feeder is empty, the
set is not finished and the
clear key is pressed. After the
set is diverted this error is
given.
Remove the documents and
adjust the 1st mark from the
top position correctly.
Remove the documents and
complete the diverted set
manually.
Note: reverse reading is used.
Remove the diverted
documents and complete the
set manually. Press reset to
remove the error message
and press "start" to resume
operation.
Remove the documents and
adjust the reading head.
Adjust the1st mark from the
top position correctly. When
the error still occurs, contact
your service organization.
Remove the documents and
check the used OMR code.
Remove the documents and
check the used OMR code
(flex-dongle).
information
Set size exceeded.
Incomplete set.
Wrong window position.
Stop mark read.
Unexpected accumulate
mark read.
Not enough marks.
Mulitple basic command. 3 : 121
No commands in code
1-800-658-8788
www.abcoffice.com
Error code
3 : 110
3 : 111
3 : 112
3 : 113
3 : 115
3 : 120
3 : 122

Advertisement

Table of Contents
loading

Table of Contents