Reverse reading (optional)
Optional reverse reading is available. Reverse
reading means that the insert mark is on the first
page of the set. The system will detect the end
of a set by detecting the first page of the next
set. Because of the feeding and collating
principal reverse reading has the following
limitations:
• the last mark of the code should be printed
maximally 85 mm from the top.
• enclosures and selective enclosures cannot
be handled.
Examples of OMR code
The legend for the following example is shown.
In this example feeder station 1 is the reading
feeder. The feeder stations 2 and 3 are selected
for selective feeding.
mark printed
no mark printed
accumalate
insert
or
no selective feed
wanted, mark not
printed
selective feed
wanted, mark
printed
A set of 8 sheets with two selective feeds
(station 2 and 1) and three sequence check
marks is shown. The first position is used for the
start mark which must be printed on every
sheet. The second mark position is used for the
insert/ accumulate command. The mark is
printed on the last sheet of the set (inserting is
required). Position 3 and 4 are reserved for
selective feeding from station 2 and 1. Print a
mark on position 3 when a selective feed from
station 2 is required. Print a mark on position 4
when a selective feed from station 1 is required.
Position 5, 6 and 7 are used for the sequence
check marks.
36
Sheet 1 Sheet 2 Sheet 3 Sheet 4 Sheet 5 Sheet 6 Sheet 7 Sheet 8
8.
8.1
When the system is equipped with the optional
"third fold table" and "turning unit", bottom
address applications and short folds are
possible.
When bottom address applications are used the
possible fold settings are "No fold", "Single fold"
and "Zig-zag fold". In case the "No fold" setting
inactive feeder 6
is used in the bottom address setting, the folding
inactive feeder 5
selective feeder 4
and inserting is performed the same as when
selective feeder 3
top address is selected.
selective feeder 2
reading feeder 1
8.2
After selecting the fold settings menu the
selection between "Top" or "Bottom" has to be
made (see figure below).
8.3
When "Top" address is selected shorter address
folds can be adjusted (except for the Zig-Zag
fold). The minimum address fold length is 25
mm. When the address fold is shorter than 75
mm the number of folded documents is limited
to 6 (in case of double parallel fold it is limited to