Formax 6600 Series Operator's Manual page 30

Folder/inserters
Table of Contents

Advertisement

In some cases, on request of the customer, the
reading of the basic commands can be set
reversed by the service organisation. This
means that for the insert command no mark has
to be printed and for the accumulate command
a mark has to be printed.
Code position and free area
The code must be printed minimally 15 mm
(0.59 inch) away from top and 20 mm (0.79
inch) from the bottom of the sheet. Default the
first mark from the top is set to 100 mm (3.9
inch). From the left hand and right hand side 7
mm (0.28 inch) must be kept clear. The code
must appear in the same location and have a
consistent number of marks on every page.
Note: for each additional mark one additional
line is necessary.
Length
Above the first mark and below the last mark a
space of 8,5 mm (0.33 inch) must be kept
without printing (see figure below). This means
that the minimum code area consists of 6 lines,
2 lines to print the (basic) and 4 lines free space.
Line distance may be 2,54 mm (0.1 inch) to 6,35
mm (0.4 inch).
32
Start mark
Insert/accumulate
Code width, character space and pitch
The minimum width of the code area is 7
character spaces. From left to right: first 2
characters space unprinted (5 mm; 0.20 inch),
then the track mark (3 characters or 6,3 mm; 0.4
inch) and finally 2 character spaces unprinted.
Pitch 10 or 12 is accepted. The track mark can
be printed by using the "underline" sign (__),
which must have a thickness of at least 0,2 mm.
Additional marks
When it is necessary to control more functions
in the inserter system, the use of more marks is
needed than there are in the minimum code.
The following additional functions are possible
via software options (see figure below):
• Divert & continue mark.
• Divert & stop mark.
• 1 mark: selective feed from station 1.
• 1 mark: selective feed from station 2.
• 1 mark: selective feed from station 3.
• 1 mark: selective feed from station 4.
• 1 mark: selective feed from station 5.
• 1 mark: selective feed from station 6.
• Exit control mark.
• Present on deck & continue mark.
• Present on deck & stop mark.
• Sealing control mark.
• 1, 2 or 3 marks: sequence check 4, 2 and 1.
• 1 mark: parity check (even).
• 1 mark: safety mark.
6,3 mm
8,5 mm
8,5 mm
4,2 mm
1-800-658-8788
www.abcoffice.com
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
4,2 mm

Advertisement

Table of Contents
loading

Table of Contents